Oct 03, 2019 In 1954, Amtrol invented the thermal expansion tank to control pressure build-up in closed, hot water systems. Today they are continuing to roll out efficient and reliable tanks to improve your system. The ST in-line thermal expansion tank is a perfect example of this.
Well-x-trol, Potable water well tank, Sizing instructions
Advertising
This handbook will discuss the basic sizing used
for our larger
Well-X-Trol
®
s such as WX-400, 420,
440, and 450 series. This allows you to use the
Well-
X-Trol
®
“principle of separation of air and water” on
larger jobs that are beyond the typical residential
range.
The
The
Well-X-Trol
®
models we’ll be working with in
this handbook are listed in Table 1.
The design features of these larger models allow
The design features of these larger models allow
us to apply them more creatively than the smaller
residential models found in the
Well-X-Trol
®
100,
200, and 250 series.
The Larger Well-X-Trol
The Larger Well-X-Trol
®
s are Designed and Built
for Maximum Acceptance on Each Operating
Cycle
In the smaller residential
In the smaller residential
Well-X-Trol
®
s, the design
is for basic intermittent use and for the usually
found in residential applications. Standard pressure
ranges of (20) PSIG (between pump cut-in and
pump cut-out) are used.
In these applications, full use of the maximum
In these applications, full use of the maximum
acceptance volume of the
Well-X-Trol
®
is rarely
required to meet job conditions.
Series 420 & 447
Pressure Switch
Table 1.
WX Model No.
NON-CODE
(NON-AS ME )
WX Model
No.
COD E
(ASM E)
Total
Volume
(Gallons)
Maximum
Acce ptance
Volume
(Gallons)
Maximum
Acce ptance
Factor
(MAF )
WX-401
WX-401-C
17.5
11.25
.65
WX–402
WX–402-C
25
11.25
.45
WX-403
WX-403-C
34
11.25
.33
WX-404
WX-404-C
68
34
.50
WX-405
WX-405-C
90
34
.39
WX-406
WX-406-C
110
34
.31
WX-407
WX-407-C
132
46
.35
WX-421
Not available
158
103
.65
WX-422
Not available
211
137
.65
WX-423
Not available
264
172
.65
WX-424
Not available
317
206
.65
WX-426
Not available
422
274
.65
WX-427
Not available
528
343
.65
WX-447
WX-447-C
53
34
.65
WX-448
WX-448-C
80
52
.65
WX-449
WX-449-C
106
69
.65
WX-450
WX-450-C
132
86
.65
WX-451
WX-451-C
158
102
.65
WX-452
WX-452-C
211
136
.65
WX-453
WX-453-C
264
170
.65
WX-454
WX-454-C
317
205
.65
WX-455
WX-455-C
370
239
.65
WX-456
WX-456-C
422
273
.65
WX-457
WX-457-C
528
341
.65
Based on 30 PS IG p re-charge (P
1
)
1400 Division Road, West Warwick, RI 02893 T: 401.884.6300 F: 401.885.2567 www.amtrol.com
SIZING INSTRUCTIONS
WELL-X-TROL
®
POTABLE WATER WELL TANK
Advertising
This manual is related to the following products:
Popular Brands
Popular manuals
WELL-X-TROL PROFESSIONAL
Pre-Pressurized
Water System
Tanks
WELL-X-TROL®Professional
revolutionizes
the industry
WELL-X-TROL®Professional redefined the industry with its advanced engineering and innovative product design including the pre-pressurized well tank, sealed-in air charge, and unique water chamber design. With proven performance since 1963, WELL-X-TROL
Professional continues to deliver unparalleled results making it the most trusted choice of professionals in today’s market.WELL-X-TROL Professional offers many unique features that result in consistent, reliable performance, including design elements that prevent tank corrosion and reduce wear and tear on the well pump.
Features and Benefits
Exclusive butyl diaphragm, along with the 100% corrosion resistant virgin polypropylene liner, are secured by a positive hoop ring seal for added strength and reliability. This totally integrated system outperforms other types of water chamber designs.
The stainless steel air valve is welded rather than threaded to prevent loss of air pressure.
The finest quality, custom mill steel is used in the deep drawn dome for extra strength while keeping tank weight to a minimum.
More choices mean more flexibility
WELL-X-TROL Professional offers more options and sizes than any other well tank manufacturer, including both
vertical and horizontal designs, and sizes ranging from 2 gallons to 119 gallons so you can configure a system that’s right for any application.
First on Industry Safety
Standards
WELL-X-TROL Professional tanks were the first to meet all industry standards for quality and safety. The butyl diaphragm in all models meets EPA requirements for potable water as defined in the Safe Drinking Water Act of 1986. The entire tank which includes the virgin polypropylene liner, butyl diaphragm, and acceptance fittings for a 100% corrosion resistant water reservoir is listed by NSF International Standard 61.
Advanced
design features
continue to set industry standards
■Stainless steel air valve is welded in position rather than mechanically threaded to prevent loss of air pressure and to minimize stress on the well’s pump system. It also carries a tamper-evident warning label.
■Deep-drawn steel domes offer twice the strength of rolled steel while minimizing weight.
■Unique positive hoop ring seal secures diaphragm and liner for added strength and reliability.
■Heavy duty butyl diaphragm features seamless construction for uniform strength and flexibility. It conforms exactly to the shell configuration without stretching, creasing, or forming bubbles or corners that could trap water or sediment. Butyl is the best known elastomer to prevent air loss.
■Heavy duty butyl diaphragm is extremely resistant to bacterial growth and meets FDA requirements for potable water supply.
■Virgin polypropylene liner provides a 100% corrosion resistant, non-metallic rigid water reservoir that is listed by NSF International Standard 61.
■Stainless-steel system connection withstands aggressive water.
■Exclusive welding process eliminates interior rough spots and sharp edges which prevent damage to the diaphragm and liner.
■Each finished tank is pressure tested for safety.
■Each finished tank is pre-pressurized to the most common pump cut-in pressure.
■Exterior appliance-like finish looks attractive while protecting the tank from the elements.
Dome
Hoop
Diaphragm
Liner
Dome
Amtrol Pressure Tank Ca17002 User Manual 2017
Stainless-steel
System
Connection
esp(Effective System Protection):
maximum system output with
minimal pump starts
The ESP sizing procedure covers modern residential water-use habits, increased off-peak demands and the general increase in water use that have occurred over the past twenty-five years. ESP sizing is designed to reduce pump wear and tear, and reduce energy consumption by keeping pump starts to a minimum.
Choose the amount of protection you need.
ESP I: Tank selection is based on approximately one minute minimum pump running time. This is recommended for pumps up to 3/4 H.P.
ESP II: Tank selection is based on approximately two minute minimum pump running time. This is recommended for 3/4 H.P. or larger pumps.
ESP Sizing Table
OPERATING PRESSURE - PSIG | ||||||
PUMP DISCHARGE | ESP I | ESP II | ||||
RATE GPM (Approx.) | 20/40 | 30/50 | 40/60 | 20/40 | 30/50 | 40/60 |
5 | WX-202 | WX-202 | WX-202 | WX-202XL | WX-205 | WX-205 |
7 | WX-202 | WX-202 | WX-202XL | WX-205 | WX-250 | WX-251 |
10 | WX-202XL | WX-205 | WX-205 | WX-251 | WX-251 | WX-255 |
12 | WX-205 | WX-250 | WX-250 | WX-251 | WX-255 | WX-255 |
15 | WX-250 | WX-250 | WX-251 | WX-255 | WX-302 | WX-350 |
20 | WX-251 | WX-251 | WX-255 | WX-350 | WX-350 | (2) WX-255 |
25 | WX-251 | WX-255 | WX-302 | (2) WX-251 | (2) WX-255 | (2) WX-302 |
30 | WX-255 | WX-302 | WX-350 | (2) WX-255 | (2) WX-302 | (2) WX-350 |
35 | WX-302 | WX-350 | WX-350 | (2) WX-302 | (2) WX-350 | (2) WX-350 |
40 | WX-350 | WX-350 | (2) WX-255 | (2) WX-350 | (2) WX-350 | (3) WX-302 |
WELL-X-TROL Professional
tank operation
time-tested design
WELL-X-TROL Professional1has a sealed in air chamber that is pre-pressurized before it leaves our factory. Air and water do not mix.
2When the pump starts, water enters the WELL-X-TROL Professional. Only usable water is stored.
When the pressure3in the chamber reaches cut-out pressure, the pump stops. The WELL-X-TROL Professional is filled.
When water is demanded, pressure in the air chamber forces water into the system. Since WELL-X-TROL Professional consistently delivers the maximum usable water, minimum
4pump starts are assured.
WELL-X-TROL Professional
residential
models
In-Line Models
Model | Dimensions | Total | Max. | System Drawdown | Shipping | |||
Diameter | Height | Volume | Accept. | 20/40 | 30/50 | 40/60 | Wt. (Vol.) | |
No. | (ins) | (ins) | (gals) | Factor | (gals) | (gals) | (gals) | lbs (cu ft) |
WX-101 | 8 | 12 5/8 | 2.0 | 0.45 | .8 | .7 | .6 | 5 (0.6) |
WX-102 | 11 | 15 | 4.4 | 0.55 | 1.8 | 1.5 | 1.3 | 9 (1.2) |
WX-103 | 11 | 22 1/4 | 7.6 | 0.42 | 3.1 | 2.6 | 2.2 | 15 (1.8) |
WX-104 | 15 3/8 | 17 3/4 | 10.3 | 1.00 | 4.1 | 3.5 | 3.0 | 20 (2.6) |
WX-200 | 15 3/8 | 22 | 14.0 | 0.81 | 5.6 | 4.8 | 4.1 | 22 (3.3) |
Precharge Pressure for WX-101 & WX-102 is 20 PSIG and Sys. Conn. is 3/4' NPTM.
Precharge Pressure for WX-103 is 30 PSIG and Sys. Conn. is 3/4' NPTM.
Precharge Pressure for WX-104 and WX-200 is 30 PSIG and Sys. Conn. is 1' NPTM.
Maximum Working Pressure is 125 PSIG and Maximum Working Temperature is 200° F.
WX-101 and WX-102 models available with Ultra TUF-KOTETMexterior coating option.
Stand Models
Model | Dimensions | Total | Max. | System Drawdown | Shipping | |||
Diameter | Height | Volume | Accept. | 20/40 | 30/50 | 40/60 | Wt. (Vol.) | |
No. | (ins) | (ins) | (gals) | Factor | (gals) | (gals) | (gals) | lbs (cu ft) |
WX-104-S | 15 3/8 | 19 1/4 | 10.3 | 1.00 | 4.1 | 3.5 | 3.0 | 23 |
WX-201 | 15 3/8 | 23 7/8 | 14.0 | 0.81 | 5.6 | 4.8 | 4.1 | 25 |
WX-202 | 15 3/8 | 31 5/8 | 20.0 | 0.57 | 8.0 | 6.8 | 5.9 | 33 |
WX-202XL | 15 3/8 | 38 1/4 | 26.0 | 0.44 | 10.5 | 8.8 | 7.6 | 36 |
WX-203 | 15 3/8 | 46 1/2 | 32.0 | 0.35 | —- | 10.9 | 9.4 | 43 |
WX-205 | 22 | 29 5/8 | 34.0 | 1.00 | 13.7 | 11.6 | 10.0 | 61 |
WX-250 | 22 | 36 | 44.0 | 0.77 | 17.7 | 15.0 | 12.9 | 69 |
WX-251 | 22 | 46 3/4 | 62.0 | 0.55 | 24.9 | 21.1 | 18.2 | 92 |
WX-255 | 22 | 56 3/8 | 81.0 | 0.41 | 32.6 | 27.5 | 23.8 | 103 |
WX-252 | 22 | 62 1/4 | 86.0 | 0.39 | 34.6 | 29.2 | 25.3 | 114 |
WX-302 | 26 | 47 1/4 | 86.0 | 0.54 | 34.6 | 29.2 | 25.3 | 123 |
WX-350 | 26 | 61 7/8 | 119.0 | 0.39 | 47.8 | 40.5 | 35 | 166 |
Precharge Pressure for WX-104-S thru WX-203 is 30 PSIG and Sys. Conn. is 1' NPTF.
Amtrol Pressure Tank Ca17002 User Manual Online
Precharge Pressure for WX-205 thru WX-350 is 38 PSIG and Sys. Conn. is 1 1/4' NPTF.
Maximum Working Temperature is 200° F. Maximum Working Pressure for all models except WX-252 is 125 PSIG.
Maximum Working Pressure for WX-252 is100 PSIG.
All models available with Ultra TUF-KOTETMexcept WX-104-S, WX-201, and WX-252.
All models except, WX-104S, WX-201, WX-252 are available with Pro-Access.
Underground Models
Model | Dimensions | Total | Max. | System Drawdown | Shipping | |||
Diameter | Height | Volume | Accept. | 20/40 | 30/50 | 40/60 | Wt. (Vol.) | |
No. | (ins) | (ins) | (gals) | Factor | (gals) | (gals) | (gals) | lbs (cu ft) |
WX-200-UG | 15 3/8 | 22 | 14.0 | 0.81 | 5.6 | 4.8 | 4.1 | 22 |
WX-202-UG | 15 3/8 | 30 | 20.0 | 0.57 | 8.0 | 6.8 | 5.9 | 30 (4.9) |
WX-250-UG | 22 | 33 3/8 | 44.0 | 0.77 | 17.7 | 15.0 | 13.0 | 60 (9.8) |
WX-251-UG | 22 | 44 1/8 | 62.0 | 0.55 | 24.9 | 21.1 | 15.3 | 83 (13.9) |
Precharge Pressure for WX-202-UG is 30 PSIG and Sys. Conn. is 1' NPTF Coupling.
Precharge Pressure for WX-205-UG and WX-251-UG is 38 PSIG and Sys. Conn. is 1 1/4' NPTF Coupling. Maximum Working Pressure is 125 PSIG and Maximum Working Temperature is 200° F.
WELL-X-TROL Professional
specialty residential
models
Pump Stand Models
Dimensions | Total | Max. | System Drawdown | Shipping | ||||||
Model | Height | Width | Length | Volume | Accept. | 20/40 | 30/50 | 40/60 | Wt. (Vol.) | |
No. | (ins) | (ins) | (ins) | (gals) | Factor | (gals) | (gals) | (gals) | lbs (cu ft) | |
WX-105-PS 11 | 10 9/16 | 18 1/4 | 5.3 | 0.80 | 2.1 | 1.8 | 1.6 | 13 | ||
WX-200-PS | 16 | 15 3/8 | 20 7/8 | 14.0 | 0.81 | 5.6 | 4.8 | 4.1 | 29 |
Precharge Pressure is 30 PSIG and Sys. Conn. is 3/4' NPTM Fitting for 103-PS and 105-PS; and 1' NPTF Coupling for 200-PS.
Maximum Working Pressure is 125 PSIG and Maximum Working Temperature is 200° F.
Offset Connector Models
Model | Dimensions | Total | Max. | System Drawdown | Shipping | |||
Diameter | Height | Volume | Accept. | 20/40 | 30/50 | 40/60 | Wt. (Vol.) | |
No. | (ins) | (ins) | (gals) | Factor | (gals) | (gals) | (gals) | lbs (cu ft) |
WX-202-OC | 15 3/8 | 29 | 20.0 | .57 | 8.0 | 6.8 | 5.9 | 32 (5.0) |
1” Barb Connection. 30 PSIG Precharge Pressure. 100 PSI Maximum Working Pressure. 200° (F) Maximum Working Temperature
Space Saver Model
Model | Height | Dimensions | Length | Total | Max. | System Drawdown | Shipping | ||
Width | Volume | Accept. | 20/40 | 30/50 | 40/60 | Wt. (Vol.) | |||
No. | (ins) | (ins) | (ins) | (gals) | Factor | (gals) | (gals) | (gals) | lbs (cu ft) |
WX-202-H 28 5/8 | 15 3/8 | 15 1/4 | 20.0 | 0.57 | 8.0 | 6.8 | 5.9 | 33 (4.9) |
Precharge Pressure is 30 PSIG. System connection is 1' NPTF (straight coupling connection).
Maximum Working Pressure is 125 PSIG. Maximum Working Temperature is 200° F.
Specialty Options
A new improved paint finish available only on WELL-X-TROL tanks.
This new paint has been re-formulated for outdoor applications where acids, salts and moisture can harm regular paint. It is crack proof and impermeable to moisture.
PRO Access Stainless Steel System Connection piped through the stand is available on most WELL-X-TROL models. Indicate PRO Access when ordering.
AMTROL has
innovative ways
to help you grow your business
Water Treatment Technologies
® | |
Hydrogen Sulfide Removal System | Arsenic Removal System |
Iron Removal System | Water Softening and Filtration |
Hydronic Technologies
Boiler Expansion Tanks | Water Heater Expansion Tanks | Indirect-Fired Water Heaters |
Ask for Quality. Ask for AMTROL®.
Corporate Headquarters | AMTROL Canada, Ltd. |
1400 Division Road | 275 Shoemaker Street |
West Warwick, RI 02893 | Kitchener, Ontario N2E 3B3 |
Telephone: 401-884-6300 | Telephone: 519-748-1138 |
w w w . a m t r o l . c o m Fax: 401-884-5276 | ® |
Fax: 519-748-4231 |
Part# 9015-516 MC# 4380 (7/04) © 2004 AMTROL Inc. | WELL-X-TROL is a registered trademark of AMTROL Inc. |